    摘要:

    磁性粒子成像是一种新型示踪剂成像技术,该技术利用磁性粒子在零磁场中的非线性磁化特性对被测物进行成像,其 中零磁场的精细度决定其空间分辨率,而零磁场的精细度由空间磁场梯度决定。 为了提高空间分辨率,设计了能产生大磁场梯 度的静磁场结构,将其与驱动结构组合成线型零磁场系统。 首先设计了基于圆环磁体阵列的静磁场结构,利用大梯度的静磁场 构造精细线型零磁场;其次设计了基于亥姆霍兹线圈的驱动结构及其驱动方式,确定线型零磁场扫描范围与驱动电流之间的关 系;最后计算线型零磁场系统的空间分辨率,研究磁场梯度、粒子粒径与空间分辨率之间的规律性。 实验结果表明:基于圆环磁 体阵列的静磁场结构产生的磁场梯度为 4. 804 T/ m,当使用 30 nm 磁性粒子作为示踪剂时,系统的空间分辨率为 0. 540 mm,此 时线型零磁场能在 30 mm 的范围内对被测物进行平移扫描。 证明了基于圆环磁体阵列的线型零磁场系统用于提高磁性粒子 成像分辨率的可行性。

    Abstract:

    Magnetic particle imaging is a new type of tracer imaging technology that uses the nonlinear magnetization characteristics of magnetic particles in magnetic field-free to image the measured objects. The spatial resolution is determined by the fineness of magnetic field-free, and the fineness is determined by the spatial magnetic field gradient. To improve spatial resolution, the static magnetic field structure which can produce large magnetic field gradient is combined with the driving structure to form a magnetic field-free line system. Firstly, this article designs static magnetic field structure based on ring magnet array. The large gradient static magnetic field is used to construct fine magnetic field-free line. Secondly, the driving structure is designed, which is based on Helmholtz coil and its driving method. The relationship between magnetic field-free line scanning range and driving current is determined. Finally, the spatial resolution of the magnetic field-free line system is calculated and its regularity with the magnetic field gradient and particle sizes is studied. Experimental results show the magnetic field gradient generated by the static magnetic field structure based on ring magnet array is 4. 804 T/ m, and the spatial resolution is 0. 540 mm when the 30 nm magnetic particle is used. The magnetic field-free line can scan within 30 mm range. It proves the feasibility of magnetic field-free line system based on ring magnet array for high-resolution magnetic particle imaging.

    参考文献
    相似文献
    引证文献
引用本文

姜 策,柯 丽,杜 强,祖婉妮.基于圆环磁体阵列的线型零磁场系统研究[J].仪器仪表学报,2021,(9):192-201

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-06-28
  • 出版日期: