新型高温薄膜热流传感器的研制
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TH811

基金项目:

国家自然科学基金(51905071)、辽宁省博士科研启动基金计划(2019-BS-043)、大连理工大学精密与特种加工教育部重点实验室研究基金(JMTZ201902)项目资助


Development of a new type of high temperature thin film heat flux sensor
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    航天飞行器在返回地球大气层时外表面会产生兆瓦级的热流,瞬时温升可达 1 800℃ ,为了保证飞行器的稳定安全运 行,准确实时测量飞行器热防护系统表面热流具有非常迫切和重要的意义。 针对高温热流检测的技术难题,提出了一种引线与 基底一体化的新型热流传感器结构。 结合陶瓷烧结静压成型和磁控溅射技术,通过在嵌入 PtRh6 引线的 99 氧化铝陶瓷基底端 面依次沉积 PtRh30-PtRh6 热电堆薄膜、Al 2O3 薄膜、ZrO2 薄膜,研制了一款新型高温薄膜热流传感器,并对热流传感器进行了静 态、动态性能、耐高温及重复性测试。 结果表明,所研制的传感器灵敏度可达 0. 01 μV/ (W/ m 2 )以上,传感器动态响应时间为 3. 97 s,对传感器进行 1200℃高温实验,结果显示传感器经历高温前后输出信号无明显变化,传感器最大重复性误差为 2. 38% 。 所研制的高温薄膜热流传感器可为高温热流测量和热防护系统优化提供科学依据。

    Abstract:

    When the spacecraft reenters the earth atmosphere, the outer surface of spacecraft will generate megawatt of heat flux. As a result, the instantaneous temperature rise can reach 1800℃ . In order to ensure the stability and safety of the spacecraft, it is significantly important to accurately measure the heat flux on the thermal protection system surface of the spacecraft in real time. Aiming at the technical difficulty of heat flux measurement in high-temperature condition, a novel heat flux sensor structure integrating the lead and substrate is proposed. Combining the ceramic sintering static pressing molding and magnetron sputtering technologies, a new high temperature thin film heat flux sensor was developed by sequentially depositing PtRh30-PtRh6 thermopile thin film, Al 2O3 film and ZrO2 film on the substrate surface of 99 alumina ceramics where the PtRh6 leads are embedded. Then, the static and dynamic performance, high-temperature resistant and repeatability tests were conducted. The result shows that the sensitivity of the sensor reaches better than 0. 01 μV/ (W/ m 2 ), the dynamic response time is 3. 97 s. High temperature test at 1200℃ was conducted on the sensor, the test result shows that the output signal of the sensor has no obvious change before and after the high temperature test, and the maximum repeatability error is 2. 38% . The developed high temperature thin film heat flux sensor can provide scientific basis for the high temperature heat flux measurement and thermal protection system optimization.

    参考文献
    相似文献
    引证文献
引用本文

崔云先,黄金鹏,曹凯迪,王浩宇,殷俊伟.新型高温薄膜热流传感器的研制[J].仪器仪表学报,2021,(3):78-87

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-06-28
  • 出版日期: