    摘要:

    目前串联电弧故障检测以主线路电流为判断对象,该方法容易受非线性负载正常工作电流奇异性的影响而造成误判;而且小功率支路的电弧故障特征容易被干路电流“淹没”而造成漏判。为了解决该问题,根据电弧高频电流电磁耦合机理,提出一种基于LN线不对称分布和高阶累积量识别的检测方法。通过分析电弧熄灭重燃时高频剩余磁通的耦合信号,利用高阶统计量工具计算出耦合信号的峭度值。对单一负载电弧故障、综合负载干路电弧故障和综合负载支路电弧故障等不同情况进行判断,得出统一峭度阈值。结果表明,该方法可有效检测和识别串联电弧故障。

    Abstract:

    Recently, the series arc fault detection uses the main line current as decision object, which is easy to be affected by the singularity of normal working current in nonlinear load and results in misjudgment. And the arc fault characteristic in the small power branch is easily ‘submerged’ by the main circuit current, which leads to missed judgment. In order to solve this problem, according to the electromagnetic coupling mechanism of high frequency arc current, a detection method based on asymmetrical distribution of LN lines and highorder cumulant identification is presented in this paper. Through analyzing the coupling signal of high frequency residual flux during the process of arcing extinction and reignition, the kurtosis of the coupling signal is calculated by means of the highorder cumulant statistical tool. In this paper, the arc faults in different conditions such as combined load main circuit arc fault and combined load branch circuit arc fault are analyzed and judged, and the unified kurtosis threshold is obtained. The results show that the method can be effectively used to detect and identify series arc faults.

    参考文献
    相似文献
    引证文献
引用本文

鲍光海,江润.基于磁通不对称分布的串联电弧故障检测研究[J].仪器仪表学报,2019,40(3):54-61

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-01-14
  • 出版日期: