Evaluation of transformer DC bias using multidimensional features and SHAP analysis
DOI:
CSTR:
Author:
Affiliation:

1.Chongqing Key Laboratory of Complex Systems and Bionic Control, Chongqing University of Posts and Telecommunications, Chongqing 400000, China; 2.Chongqing Research Institute of Beijing University of Technology, Chongqing 401121, China; 3.Yinchuan Power Supply Company, State Grid Ningxia Electric Power Co., Ltd., Yinchuan 750011, China; 4.Chongqing Hongyu Precision Industry Group Co., Ltd., Chongqing 401120, China

Clc Number:

TM41;TN911.7

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To address the issues of insufficient generalization ability in traditional single-index diagnosis methods under complex operating conditions, and the opacity of the decision-making process in conventional machine learning models (the “black box” problem) for transformer DC bias condition assessment, this paper proposes an accurate assessment model based on multi-dimensional feature fusion and Shapley additive explanations (SHAP) interpretability analysis. First, based on the analysis of the vibration response mechanism of transformers under different degrees of DC bias, a 14-dimensional feature system fusing time-domain statistics, frequency-domain harmonic components, and specific physical mechanism features (such as weighted odd-even harmonic energy ratio and spectral entropy) is extracted and constructed. Next, a recursive feature elimination (RFE) strategy based on SHAP importance is utilized to adaptively screen the feature set, effectively eliminating redundant features. On this basis, the extreme gradient boosting (XGBoost) algorithm is adopted to build the assessment model, and Bayesian optimization is employed to adaptively tune the model hyperparameters, achieving precise identification of DC bias severity levels. Experimental verification based on multiple measurement points indicates that the optimized model can adaptively select the optimal feature subset for different sensor locations, achieving an assessment accuracy of over 96.2% across all tested points. Finally, the SHAP framework is introduced to quantitatively analyze the model’s decision-making mechanism from both global and local perspectives. The interpretability results demonstrate a high consistency between the model’s decision basis and the physical laws of vibration transmission and DC bias. This method demonstrates excellent interpretability while ensuring high diagnostic accuracy, providing a transparent and reliable solution for the engineering application of data-driven models in the field of transformer condition assessment.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: October 13,2026
  • Published:
Article QR Code