高灵敏度非接触式差频溶液电导率检测系统
DOI:
CSTR:
作者:
作者单位:

上海海洋大学工程学院上海201306

作者简介:

通讯作者:

中图分类号:

TN98

基金项目:


High-sensitivity non-contact differential frequency solution conductivity detection system
Author:
Affiliation:

School of Engineering Science and Technology, Shanghai Ocean University, Shanghai 201306, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    侵入式的电极式测量法在电导率测量系统中的应用较为广泛,但因其存在腐蚀电极和极化效应等问题,国内外学者对非侵入式的电磁式电导率测量法开展了大量研究,其中大部分电磁式电导率测量法属于传统的定频调幅式测量电路,信号处理电路较为复杂,且易受到噪声干扰从而带来测量误差。也有部分学者通过频率来测量电导率,但由于没有选择合适的测量方法和激励频率,导致测量效果不佳,检测系统灵敏度较低。针对上述问题,设计了一款高灵敏度非接触式差频溶液电导率检测系统,从理论上分析了电解质溶液的涡流会影响线圈的阻抗,通过增加激励频率并将检测线圈浸入溶液中可显著提高系统灵敏度,检测线圈经过防水处理不与溶液直接接触。检测系统将线圈电感的变化转化成频率的变化,通过测量线圈的差动频率来测量溶液电导率,这种差动结构可以减小外部干扰对检测系统的影响。通过标定实验验证了该测量方法的可行性,检测系统在测量低电导率溶液时灵敏度高达54 485 Hz/(mS·cm-1),总体的平均灵敏度为34 340 Hz/(mS·cm-1)。根据标定实验得出电导率与差动频率的拟合方程,通过对比精度和校准补偿两个实验结果可知,校准补偿后大部分测量的相对误差在5%以内,校准后整体误差和校准前相比有所降低,体现了测量前校准补偿的重要性。实验对象包括NaCl和KCl两种电解质溶液,结果表明这两种溶液的电导率都会对差动频率产生影响,说明结论的可靠性和普适性。

    Abstract:

    Invasive electrode-based measurement methods are widely used in conductivity measurement systems. However, due to issues such as electrode corrosion and polarization effects, scholars at home and abroad have conducted extensive research on non-invasive electromagnetic conductivity measurement methods. Most of these electromagnetic conductivity measurement methods rely on traditional fixed-frequency amplitude-modulated measurement circuits, which have complex signal processing circuits and are susceptible to noise interference, resulting in measurement errors. Some scholars also measure electrical conductivity by frequency, yet they fail to adopt proper measurement methods and excitation frequencies, resulting in poor measurement performance and low detection system sensitivity. To address the above-mentioned problems, a high-sensitivity non-contact differential frequency solution conductivity detection system is designed. Theoretically, it is analyzed that the eddy current in the electrolyte solution will affect the impedance of the coil. Increasing the excitation frequency and immersing the detection coil into the solution can significantly improve system sensitivity. The detection coil is waterproofed to avoid direct contact with the solution. The detection system converts the change in coil inductance into a change in frequency, and measures the conductivity of the solution by detecting the differential frequency of the coil. This differential structure can reduce the impact of external interference on the detection system. The feasibility of this measurement method was verified through calibration experiments. The detection system achieves a high sensitivity of 54 485 Hz/(mS·cm-1) when measuring low-conductivity solutions, with an overall average sensitivity of 34 340 Hz/(mS·cm-1). Based on the calibration experiment, the fitting equation between conductivity and differential frequency was derived. By comparing the results of the accuracy experiment and the calibration compensation experiment, it can be seen that the relative error of most measurements is within 5% after calibration compensation. Compared with that before calibration, the overall error after calibration is reduced, which reflects the importance of calibration compensation before measurement. The experimental objects are two electrolyte solutions, namely NaCl and KCl. The results indicate that the electrical conductivity of both solutions exerts an influence on the differential frequency, which proves the reliability and universality of the conclusion.

    参考文献
    相似文献
    引证文献
引用本文

黄哲,吴帅,朱建平,吕春峰.高灵敏度非接触式差频溶液电导率检测系统[J].电子测量与仪器学报,2026,40(9):79-88

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-11-13
  • 出版日期:
文章二维码
×
《电子测量与仪器学报》
关于防范虚假编辑部邮件的郑重公告