应用于ATE的多通道高精度TDC测量系统设计
DOI:
CSTR:
作者:
作者单位:

合肥工业大学微电子学院合肥230009

作者简介:

通讯作者:

中图分类号:

TN98

基金项目:

国家自然科学基金重大科研仪器研制项目(62027815)资助


Design of multi channel high precision TDC measurement system applied to ATE
Author:
Affiliation:

School of Microelectronics, Hefei University of Technology, Hefei 230009, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    随着集成电路产业的飞速发展,芯片引脚数和内部信号数量持续增加,传统单通道方案难以应对大规模并发测量挑战,对多通道信号的协同测试与时序的要求也日益严苛。针对集成电路自动测试设备(automatic test equipment,ATE)中时间数字转换器(time-to-digital converter,TDC)的高精度测量需求,提出一种多通道高精度TDC测量系统:以现场可编程门阵列(field-programmable gate array,FPGA)作为核心控制单元,结合高精度TDC专用芯片构建异构时间间隔测量单元;采用低抖动时钟芯片提供多路相位一致的同步时钟信号,构建精密的全局同源参考时基,实现对多通道TDC的精准同步。所设计的系统首先将八路输入信号经过高速比较器进行电平调理转为TDC触发信号,和同步信号共同作为TDC测量信号,TDC通过分别测量每个通道与同步信号的绝对时间间隔,进而通过后端数字逻辑解算得到任意两通道间的高分辨时间间隔。实验表明,校准后两通道测量时精度优于13.4 ps,多通道测量时通道间测量精度优于21.79 ps。

    Abstract:

    With the rapid development of the integrated circuit industry, the number of chip pins and internal signals is continuously increasing. Traditional single-channel architectures can no longer meet the test challenges of large-scale concurrent measurements, and the requirements for collaborative testing and timing precision of multi-channel signals are becoming increasingly stringent. To address the high-precision measurement demands in automatic test equipment (ATE), a multi-channel, high-precision time-to-digital converter (TDC) measurement system is proposed. This system utilizes a field programmable gate array (FPGA) as the core control unit, integrating dedicated high-precision TDC chips to construct a heterogeneous time interval measurement architecture. A low-jitter clock generator is employed to provide multiple phase-aligned synchronous clock signals, establishing a precise global homologous reference time base to achieve rigorous synchronization across multi-channel TDCs. In the designed system, the eight-channel input signals are first processed by high-speed comparators for level conditioning to generate TDC trigger signals. These signals, together with the synchronous clock, serve as the measurement inputs for the TDCs. By independently measuring the absolute time interval between each channel and the synchronization signal, the system subsequently calculates the high-resolution time intervals between any two arbitrary channels through backend digital logic. Experimental results demonstrate that, after calibration, the measurement precision is better than 13.4 ps for dual-channel operation, and the inter-channel measurement precision is better than 21.79 ps during multi-channel concurrent operation.

    参考文献
    相似文献
    引证文献
引用本文

李帮金,刘士兴,于霄,许家诚,梁华国.应用于ATE的多通道高精度TDC测量系统设计[J].电子测量与仪器学报,2026,40(9):54-61

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-11-13
  • 出版日期:
文章二维码
×
《电子测量与仪器学报》
关于防范虚假编辑部邮件的郑重公告