FVIM-MVMD结合样本熵的MEMS陀螺仪去噪方法研究
DOI:
CSTR:
作者:
作者单位:

西南石油大学电气信息学院成都610500

作者简介:

通讯作者:

中图分类号:

TN98;TP732

基金项目:

国家自然科学基金(121710730)项目资助


Research on MEMS gyroscope denoising method combining FVIM-MVMD with sample entropy
Author:
Affiliation:

College of Electrical and Information Engineering, Southwest Petroleum University, Chengdu 610500, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对常规微机电陀螺仪精度低,角速度信号随机噪声的问题,提出了一种基于四向量优化算法优化多元变分模态分解的信号处理方法。首先利用MVMD对收集到的角速度信号进行处理,将其划分为频率和能量两个组成部分。其次利用FVIM对模态分解的两个关键参数(模态数k和惩罚因子α)进行优化,得到参数的最优组合。继而,将信号分解成多个本征模态函数分量,并利用样本熵结合余弦相似度作为联合判定准则,将IMFs分量区分为噪声分量、混叠分量和有效分量。再利用小波算法对混叠分量进行处理,处理后与筛选出的有效分量进行重构,得到去噪后的角速度信号。最后进行了实验验证,将所提出的方法应用于仿真信号和采集的实测信号,结果表明仿真信号处理时均方根误差降低57.1%,实测的Y轴角速度信号与Z轴角速度信号随机游走值分别降低76.9%和56.2%。

    Abstract:

    Aiming at the problems of low accuracy and random noise in angular velocity signals of conventional Micro-Electro-Mechanicals gyroscopes, a signal processing method based on multivariate variational mode decomposition (MVMD) optimized by four-vector intelligent metaheuristic (FVIM) is proposed in this paper. Firstly, the collected angular velocity signals are processed by MVMD, and divided into two components of frequency and energy. Secondly, the FVIM is utilized to optimize the two key parameters of modal decomposition, namely the number of modes k and the penalty factor α, so as to obtain the optimal combination of parameters. Then, the signals are decomposed into multiple intrinsic mode function (IMF) components, and sample entropy (SPN) combined with cosine similarity is taken as the joint decision criterion to classify the IMF components into noise components, aliasing components and effective components. Furthermore, the wavelet transform (WT) algorithm is adopted to process the aliasing components, and the processed components are reconstructed with the screened effective components to obtain the denoised angular velocity signals. Finally, experimental verification is conducted by applying the proposed method to both simulation signals and actual measured signals. The results show that the root mean square error is reduced by 57.1% during simulation signal processing, and the random walk values of the measured Y-axis and Z-axis angular velocity signals are decreased by 76.9% and 56.2% respectively.

    参考文献
    相似文献
    引证文献
引用本文

陆金波,范立华,茜永亮,刘西成,裴桢. FVIM-MVMD结合样本熵的MEMS陀螺仪去噪方法研究[J].电子测量与仪器学报,2026,40(8):58-68

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-10-13
  • 出版日期:
文章二维码
×
《电子测量与仪器学报》
关于防范虚假编辑部邮件的郑重公告