    摘要:

    增大信噪比是提高非接触式超声波流量计测量精度的有效措施。 但通过提高发射电压来增大信噪比,会损坏超声波传 感器与接收电路,也会加剧收发电路的相互干扰。 设计了一种针对复合管道流量测量用的超声波收发电路:在发射电路中以中 轴变压器替代阻尼电阻,在接收电路中采用限幅桥电路来保护接收电路,并基于匹配电阻法来平衡收发电路。 实验结果表明, 设计的发射电路能够提高发射电压、减小放电时间,空载时对输出电压可放大 13. 85 倍,带载时对输出电压可放大 4. 5 倍,同 时,接收电路能够有效抑制收发电路的相互干扰,并提高接收支路功率,接收电路对 5 V 以下信号的传输效率超过了 90%。 把 该电路应该到非接触式超声波流量计中,对难于穿透的复合管道中的流体进行多次重复测量,测试结果表明,该流量计的线性 度和重复性都满足实际流量测量要求。

    Abstract:

    The increase of signal-to-noise ratio ( SNR) is an effective measure to improve the measurement accuracy of an ultrasonic flowmeter. However, the increase of transmission voltage for higher SNR could damage the ultrasonic sensor and the receiving circuit; it also introduces higher mutual interference between the transmitting and receiving circuits. Proposing an ultrasonic transceiver design for flow measurement of composite pipes: In the transmission circuit, a central-axis transformer instead of a damping resistor is used. In the receiving circuits, a limiting bridge circuit is employed for protection. The experimental results showed that the optimized transmission circuit proposed in this paper could increase the transmission voltage and reduce the discharge time. The output voltage is amplified by 13. 85 and 4. 5 times without and with loads, respectively. At the same time, the receiving circuit can effectively suppress the mutual interference and improves the power of the receiving branch. The transmission efficiency of the receiving circuits for signals below 5 V exceeds 90%. The circuit design was applied to a non-contact ultrasonic flowmeter, and the fluid in the composite pipeline was measured. The test results showed that the linearity and repeatability of the flowmeter had met the actual requirements of the flow measurement.

    参考文献
    相似文献
    引证文献
引用本文

贾惠芹,王成云,张铁煜,白永鑫.非接触式超声波流量计收发电路的设计与性能分析[J].电子测量与仪器学报,2020,34(9):123-132

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-11-20
  • 出版日期: