Novel method for flue gas flow of gas turbines in offshore oil production facilities
DOI:
CSTR:
Author:
Affiliation:

1.Department of Building Engineering,Hunan Institute of Engineering,Xiangtan 411104,China; 2. Hunan Engineering Research Center of Energy Saving and Material Technology of Green and Low Carbon Building, Xiangtan 411104, China; 3.Hunan Zunfeng Electromechanical Technology Co., Ltd. Huaihua 418099

Clc Number:

TK-9

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The flue gas flow is an important parameter to determine the capacity of waste heat boiler in offshore oil production facilities. In this paper, the excess air coefficient α is calculated by measuring the combustion products (such as O2, RO2, etc.) of gas fuel by gas analyzer on the basis of given gas fuel composition and fuel characteristic coefficient, and then the flue gas flow of gas turbine is calculated . The results show that under different loads, the α value of gas turbine varies from 3 to 7, which is significantly greater than that of boiler. This measurement method has important reference value for engineering application of gas turbine flue gas waste heat recovery in offshore oil production facilities.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: November 25,2024
  • Published:
Article QR Code