面向重症监护室患者的无线体征监测系统设计
DOI:
CSTR:
作者:
作者单位:

1.北京理工大学自动化学院 北京 100081; 2.北京航天动力研究所 北京 100076

作者简介:

通讯作者:

中图分类号:

TH86;TN92

基金项目:

北京自然科学基金(3232014)、北京市科技计划(Z251100006025017)项目资助


Wearable wireless vital sign monitoring system for patients in intensive care units
Author:
Affiliation:

1.School of Automation, Beijing Institute of Technology,Beijing 100081, China; 2.Beijing Aerospace Propulsion Institute,Beijing 100076, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    重症监护室(ICU)作为救治危重病患的核心场所,承担着对重症患者进行全天候监护和治疗的重要职责。然而,目前国内ICU中普遍采用的生命体征监测系统仍以有线设备为主,存在诸多局限性。因此,提出了一款无线体征监测系统,佩戴于患者的腕部和指尖使用,可以实时采集患者的体温、心率和血氧饱和度,并将结果上传至手机和云平台数据库显示。对比现阶段使用的有线监护仪,该设备小巧且易于穿戴,大大提高了患者的舒适度和自由度,同时有效减少了患者与仪器的物理接触,降低感染风险。在静息状态下,同时佩戴该无线监测设备、华为手环和医用指夹式心率血氧仪(作为标准)对同一人体进行检测。结果表明,该无线监测设备测量的心率数据标准误差为0.15,血氧数据的标准误差为0.065;华为智能手环测量的心率数据标准误差为0.48,血氧数据的标准误差为0.13。由此可得该无线监测设备的测量准确度高于华为智能手环,连续监测和数据记录性优于指夹式心率血氧仪,对ICU迈向智能化有深远意义。

    Abstract:

    The intensive care unit serves as a central hub for treating critically ill patients, with the essential responsibility of providing continuous monitoring and care for severe cases. However, the current vital sign monitoring systems used in most domestic ICUs mainly depend on wired equipment, which comes with various limitations. This paper presents a wireless vital sign monitoring system that can be comfortably worn on the patient′s wrist and fingertips to address this issue. This system is designed to collect real-time data on the patient′s body temperature, heart rate, and blood oxygen saturation levels. The collected data is then uploaded to both a mobile phone and a cloud-based database for easy access and display. Compared to the existing wired monitors, this device is compact, easy to wear, and enhances patient comfort and mobility. It also reduces physical contact with the equipment, decreasing the infection risk. During testing, one individual wore the wireless monitoring device alongside a Huawei smart band and a medical-grade finger-clip heart rate and blood oxygen monitor (considered the standard) while resting. The results indicated that the standard error for heart rate data from the wireless monitoring device was 0.15, while for blood oxygen data, it was 0.065. In contrast, the Huawei smart band showed a standard error of 0.48 for heart rate data and 0.13 for blood oxygen data. These findings suggest that the wireless monitoring device provides greater measurement accuracy than the Huawei smart band and outperforms the finger-clip heart rate and blood oxygen monitor in terms of continuous monitoring and data recording capabilities. This advancement is significant for the evolution of intelligent ICUs.

    参考文献
    相似文献
    引证文献
引用本文

师嘉仪,胡慧,赵蓉恒,王涛,任帅.面向重症监护室患者的无线体征监测系统设计[J].电子测量技术,2026,49(9):51-57

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-06-08
  • 出版日期:
文章二维码

重要通知公告

①《电子测量技术》期刊收款账户变更公告